This datalogger is designed mainly for registration of output from
tipping bucket raingauges with contact closure output signal. The
datalogger firmware checks each midnight the system operation and
stores the result in the data memory. Therefore, the user is sure
about the data reliability (in case of long period without rain for
instance, when might be some doubts about the proper operation).
When a problem appears in a certain day due to power supplying (low
battery voltage) or for a hardware failure, the user’s attention is
pointed to this day during the data conversion.
- Sensors to be connected
tipping bucket raingauge – contact
- Resolution
1 sec
- Data memory size
32 KB
- Accuracy of internal clock
±1 minute per month (-10 to 40 °C)
- Power supply
three AA alkaline batteries
- Idle
0.02 mA
Close contact – operating
30 mA
- Battery life
few years
- IP rating
55
- Size
11 x 11 x 6 cm
- Weight
300 g
|